SLC System, 5/03 RS Programmer Cable, 10Ft., (3M). Catalog No: CP3 Codale Item No: UPC: UNSPSC 06/19/ PM. Access Level. Everyone. CP3/CP3 Cable Pinout. Question. What is the pin out for the CP3/CP3. The KE module is a communication interface module that acts as a bridge between .. The figures below show male connectors, and their pinout locations, for. Allen-Bradley Personal Computer Using a CP3 cable. KE .

Author: Balkis Faejas
Country: Algeria
Language: English (Spanish)
Genre: Business
Published (Last): 1 February 2018
Pages: 267
PDF File Size: 15.12 Mb
ePub File Size: 6.24 Mb
ISBN: 175-9-60780-330-1
Downloads: 38085
Price: Free* [*Free Regsitration Required]
Uploader: Dourg

With most modern PLCs, all you need to start programming or troubleshooting pinlut to plug in your laptop with a plain old ethernet cable. Older PLCs, however, tend to use a myriad of different cables and protocols.

Rockwell Automation

With a large number of legacy systems, the original programming cables and software are often long lost by the time you want to make updates or need to troubleshoot an issue. This blog post summarizes the different ways that you can connect to these PLCs and some of the pitfalls to look out for.

  HP1020 ZSR.DLL PDF

If you have access to oinout original PLC program typically a. RSS file and a copy of the RSLogix programming software contact your A-B distributor if you need oneyou can open the project and check the communication settings by double-clicking on Channel Configuration under the controller section of the project tree:.

Scripting must be enabled to use this site.

As you can see, each model features a slightly different set of physical ports and protocols. The two most common ways to connect are DH and DF1.

The official A-B cable is CP3. In addition, you will need the female-to-female null modem crossover DB9 serial cable or a straight-through RJ45 ethernet cable, depending on which port you want to connect to. Make sure you 1747c-p3 set the selector switch to RS or RS There is one potential pitfall: However, it is possible to configure it in the PLC settings to be, or baud at as well. The UIC adapter only supports pinoout out of the box.

  HEAT EXCHANGER DESIGN HANDBOOK KUPPAN PDF

You will need to set up the connection in the RSLinx software. Once you plug in your cable and Windows installs any necessary drivers, it should show up in Device Manager as a COM port.

The driver should be able to figure out the correct settings. Here is a link to the SLC user manual. Here are some general tips on working with legacy hardware.

Name required Name Is Required. Notify me of pinoht comments via e-mail. RSS file and a copy of the RSLogix programming software contact your A-B distributor if you need oneyou can open the project and check the communication settings by double-clicking on Channel Configuration under the controller section of the project tree: Wednesday, February 7, 8: